Default Mask Parameters - Symmetricom EDGE CLOCK 1000 User Manual

Edge clock
Table of Contents

Advertisement

<aid>
<keyword>
GPS, PRS,
MASK
INP1, INP2
MTIE-1
GPS
MTIE-5
(cont'd)
MTIE-10
MTIE-50
MTIE-100
MTIE-500
FFOFF-60
Table 4-2. Default Mask Parameters
MTIE-1
Default
10 000
GPS-R
150
PRS
10
DS1
302
OCN
600
PRC
25
TYPE I
750
TYPE II
302
Sample Command
SET-TH::GPS:TS1000::MASK=GPS-R;
This command sets the GPS input performance monitoring threshold to a mask
value of GPS-R.
097-58001-02 Revision G – April 2008
<value>
DEFAULT
GPS-R
PRS
DS1
OCN
PRC
TYPEI
TYPEII
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
1 to 5 000 000
100 to 10 000 000
MTIE-5
MTIE-10
50 000
100 000
150
150
10
12
312
325
1000
1000
25
25
750
1000
312
325
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Description
Set the MTIE-x and FFOFF-60 thresholds to
predefined settings.
values for each setting.
1-second MTIE observation threshold in ns
5-second MTIE observation threshold in ns
10-second MTIE observation threshold in ns
50-second MTIE observation threshold in ns
100-second MTIE observation threshold in ns
500-second MTIE observation threshold in ns
Set FFOFF threshold for 60-second
calculation period, in ps/s
MTIE-50
MTIE-100
500 000
1 000 000
150
150
25
39
325
550
1000
1000
25
39
2000
2000
425
1000
Table 4-2
describes the
MTIE-500
FFOFF-60
5 000 000
10 000 000
155
50 000
155
1000
1002
12 000
1002
370 000
155
1000
2000
2900
1000
1000
TimeProvider User's Guide 117