Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Table 4-3. Alarm Conditions and Defaults (Continued)
Description of Alarm
Alarm ID
Condition
CLKWARM
Local oscillator on the
specified IOC is in
Warm-up mode
CLKFREE
Local oscillator on
specified IOC is in
Free-run mode
CLKBRDG
Local oscillator on
specified IOC is in
Bridging mode
CLKHOLD
Local oscillator on
specified IOC is in
Holdover mode
INPDISQ
Specified input has
been disqualified or
qualified as a possible
system reference.
INPLOS
Specified input has
Loss Of Signal.
INPFRQ
Specified input has
calculated received
frequency that exceeds
the pull-in range of the
LO.This alarm condition
disqualifies the input as
a possible reference.
INPPHASE
Specified input port's
phase measurement
exceeds usable value.
EXDSC
Input has had excessive
discontinuities, indicated
by more than 3 signal
faults (OOF, BPV, CRC,
or AIS) within a 5-minute
window. The alarm
clears when the
5-minute window
contains less than 3
signal faults.
128 TimeProvider User's Guide
Possible
Alarm
Levels
MN | MJ
IMMED
MN | MJ |
IMMED
CR
MN | MJ |
IMMED
CR
MN | MJ |
IMMED
CR
<aid> = PRS
MN | MJ |
FLT
CR
DELAY
MN | MJ |
IMMED
1
CR
NR | NA |
IMMED
MN | MJ |
CR
2
NR | NA |
IMMED
MN | MJ |
CR
NR | NA |
IMMED
MN | MJ |
CR
Error
Error
Delay
Delay
Default
Editable?
No
No
No
No
Yes
No
No
No
No
097-58001-02 Revision G – April 2008
Default Level
SSU
SUB
Mode
Mode
MN
MN
MJ
MJ
MJ
MJ
MJ
MJ
MN
MN
MN
MN
MN
NR
MN
MN
MN
MN