Symmetricom EDGE CLOCK 1000 User Manual page 92

Edge clock
Table of Contents

Advertisement

Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters
Setting the Handshaking (Flow) Mode
Use the ED-EQPT command to provision the handshaking mode on the local Craft
or Remote port to None, Hardware, Software, or Hardware/Software.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
COMp
FLOW
p = L | R
Sample Command
ED-EQPT::COML:TS1000::FLOW=HW;
Normal Response
M
;
Setting the Echo Mode
Use the ED-EQPT command to provision the echo mode on the local Craft or
Remote port to On or Off. When set to ENABLE, characters you type at the
keyboard also appear on the monitor. If one keystroke generates two characters on
the monitor, set this parameter to DISABLE.
You can also use ED-EQPT to echo the <tid> in the response from the TimeProvider.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];
This command has a default access level of ADMIN.
<aid>
<keyword>
COMp
ECHO
p = L | R
TIDQUIET
Sample Command
ED-EQPT::COML:TS1000::ECHO=ENABLE;
Normal Response
M
;
92
TimeProvider User's Guide
<value>
NONE | SW |
HW | SWHW
TIMEPROVIDER 03-10-24 10:12:33
TS1000 COMPLD
<value>
ENABLE | DISABLE
ENABLE | DISABLE
TIMEPROVIDER 03-10-24 10:15:04
TS1000 COMPLD
Description
Flow control
Description
Input echo
Enables or disables the
echo of the <tid>. This
is a session setting.
097-58001-02 Revision G – April 2008
Default value
NONE
Default value
DISABLE
DISABLE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edge clock 1100Timeprovider 1000Timeprovider 1100