Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Table 6-7. Alarm Codes (Continued)
Event ID
Description
CLK
Local oscillator in the specified
BRDG
IOC is in Bridging mode.
CLK
Local oscillator in the specified
HOLD
IOC is in Holdover mode.
CLK
Local oscillator in the specified
FREE
IOC is in the Free-run mode.
CLK
Local oscillator in the specified
WARM
IOC is in the Warm-up mode.
SYNTH
Synthesizer generating the
EOR
output frequency has reached a
defined End-of-Range for the
oscillator.
IOC2
Communication alarm with IMC
COMM
and IOC2.
IOC2TO
Communication alarm from
1 COMM
IOC2 to IOC1.
IOCFAIL
Summary alarm for IOC
hardware failures not specified
in other alarms.
BTBCK
All BesTime backup sources
UP
are unusable to the BesTime
engine.
CLK
Local oscillator in the specified
BRDG
IOC is in Bridging mode.
CLK
Local oscillator in the specified
HOLD
IOC is in Holdover mode.
CLK
Local oscillator in the specified
FREE
IOC is in the Free-run mode.
CLK
Local oscillator in the specified
WARM
IOC is in the Warm-up mode.
SYNTH
Synthesizer generating the
EOR
output frequency has reached a
defined End- of-Range for the
oscillator.
178 TimeProvider User's Guide
AID
Service
TYPE
Affecting
EQPT
NSA
EQPT
SA
EQPT
SA
EQPT
SA
EQPT
SA
AID = IOC2
EQPT
NSA
EQPT
NSA
EQPT
SA
EQPT
NSA
EQPT
NSA
EQPT
SA
EQPT
SA
EQPT
SA
EQPT
SA
AID = GPS
Alarm Level
SSU
PRR
Mode
Mode
Mode
NA
NA
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MN
MN
MN
MJ
MJ
MJ
MN
MN
MN
MN
MN
MN
MJ
MJ
MJ
NA
NA
NA
NA
NA
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MN
MN
MN
MJ
MJ
MJ
097-58001-02 Revision G – April 2008