Table 6-6. Set and Clear Conditions for Alarms (Continued)
Alarm ID
Set Alarm Conditional Description
BTBCKUP
BesTime backup reference disqualified
CLKBRDG
Clock entered Bridging mode
CLKFREE
Clock entered Free-run mode
CLKHOLD
Clock entered Holdover mode
CLKWARM
Clock entered Warm-up mode
SYNTHEOR
Output generator exceeded pull-in
range
ANTCOMM
GPS antenna communication fault
GPSPOS
GPS antenna position unknown
GPSPWR
GPS power fault
GPSSYS
GPS system fault
GPSTRK
GPS is not tracking satellites
INPDISQ
GPS input is disqualified
INPLOS
LOS fault
INPFRQ
Frequency threshold exceeded
INPPHASE
Phase error exceeded threshold
EXDSC
Excessive discontinuity fault
FFOFF
FFOFF exceeded threshold
MTIE
MTIE exceeded threshold
TPIUSIG
TPIU signal fault
INPDISQ
Input disqualified as possible reference
INPAIS
AIS fault
INPLOS
LOS fault
INPOOF
OOF fault
INPFRQ
Frequency threshold exceeded
INPPHASE
Phase error exceeded threshold
INPQL
Quality Level (SSM) exceeded
threshold
097-58001-02 Revision G – April 2008
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Clear Alarm Conditional Description
BesTime backup sources qualified
Clock exited Bridging mode
Clock exited Free-run mode
Clock exited Holdover mode
Clock exited Warm-up mode
Output generator within pull-in range
GPS Codes
GPS antenna comm fault cleared
GPS antenna position known
GPS power fault cleared
GPS system OK
GPS is tracking satellites
GPS input is enabled
LOS fault cleared
Frequency within threshold
Phase error within threshold
Excessive discontinuity cleared
FFOFF within threshold
MTIE within threshold
TPIU signal fault cleared
PRS and INP[p] Codes
Input qualified as possible reference
AIS fault cleared
LOS fault cleared
OOF fault cleared
Frequency within threshold
Phase error within threshold
Quality Level (SSM) within threshold
Troubleshooting the TimeProvider