Table 6-5. Event Codes (Continued)
Keyword
Event ID
Description
FREEFLT
Indicates if the Output
Fault is issued when
the local oscillator
enters Free-Run
mode.
GPSCLR
The time, in seconds,
DEL
after a cleared GPS
fault can be used.
GPSFLTDEL
Time, in seconds,
before a GPS fault
indicated it is not valid
HOLDFLT
Indicates if the Output
Fault is issued when
the local oscillator
enters Holdover mode
INPREF
Indicates if the system
automatically selects
another reference
input. Operator has
enabled the selected
reference input
(REFMODE must be
set to FORCED)
LOCTIM
The local system time
offset has changed
REFMODE
Indicates if the system
reference can be
selected automatically
or by the user
TIMCHG
The system time has
been changed
097-58001-02 Revision G – April 2008
Chapter 6 Maintaining and Troubleshooting the TimeProvider
AID
Default Value/
TYPE
Keyword
EQPT
SQUELCH
EQPT
5 s
EQPT
1 second
EQPT
ON
T1
PRS
EQPT
(00)-00
EQPT
AUTO
EQPT
hh-mm-ss
Troubleshooting the TimeProvider
Description of Values
ON – In fault mode, generate
outputs based on system SSM
AIS – In fault mode, generate
AIS outputs
SQUELCH – In fault mode,
outputs are turned off
0 to 1000 s
1 to 1000 s
ON – In fault mode, generate
outputs based on system
SSM
AIS – In fault mode, generate
AIS outputs
SQUELCH – In fault mode,
outputs are turned off
PRS – PRS input is selected
as reference
INP1 – INP1 is selected as
reference
INP2 – INP2 is selected as
reference
±
(hh) – hours offset
12
mm – minutes offset 00 to 59
AUTO – System uses
QLEVEL and Priority to select
the system reference
FORCED – User selects the
system reference. If the
selected reference fails, this
value reverts to AUTO mode
hh – hours (24-hour clock)
mm – minutes
ss – seconds
TimeProvider User's Guide 173