Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Table 6-5. Event Codes (Continued)
Keyword
Event ID
Description
XFEROK
Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the redundant
IOC was successful
CLKTYPE
The specified IOC
clock has been set to
the specified value.
This value is used to
define the IOCs pull-in
range and SSM
generation in Holdover
mode
INPREF
The specified input
has been set as the
system reference
IOCMODE
The specified IOC has
become Active
IOCSTATE
The specified IOC has
been inserted into the
system. The IOC is
automatically placed
In-Service
The specified IOC has
been taken out of
service. The IOC can
no longer generate
alarms, be
provisioned, or accept
queries
Communication
between the IMC and
IOC has failed
The specified IOC has
been removed from
the system
170 TimeProvider User's Guide
AID
Default Value/
TYPE
Keyword
EQPT
n/a
IOC Event Codes
EQPT
TYPEI
EQPT
PRS
EQPT
ACTIVE
EQPT
INSRV
Description of Values
n/a
ST3E | TYPE I
ST2 | TYPE II
PRS | INP1 | INP2
ACTIVE | STANDBY
INSRV – In service
OOSRV – Out of service
COMMFLT –
Communications fault
UNEQUIPPED