Adding A User - Symmetricom EDGE CLOCK 1000 User Manual

Edge clock
Table of Contents

Advertisement

Chapter 4 Provisioning the TimeProvider
Managing the User List
Sample Command
CANC-USER::TECHNICIAN:TS1000;
This command logs out the user named Technician.
Autonomous Message
A 1171 REPT EVT
OUT,TECHNICIAN\""
;

Adding a User

You can store up to 20 users in the TimeProvider's user list. Each user has a name
of up to 20 case-insensitive alphanumeric characters, a password of up to 20
case-sensitive characters, and one of the four defined access levels.
Use the following TL1 command to add a user to the user list. If more than 20 users
are defined in the user list, the DENY response is sent. Only a Security-level user
can add to the user list.
ENT-USER-SECU:[<tid>]:<uid>:[<ctag>]::<pid>,<uap>;
This command always has an access level of SECURITY.
Parameter
<uid>
<username>
<pid>
<user password>
<uap>
NONE | USER |
ADMIN | SECURITY
Sample Command
ENT-USER-SECU::TECHNICIAN:TS1000::TECH01!,USER;
This command creates a user named TECHNICIAN with a password of TECH01! at
the User access level.
Autonomous Message
A 1172 REPT EVT
ADDED\""
;
98
TimeProvider User's Guide
TP-SSU 03-10-24 10:25:31
"IMC,EQPT:NA,LOGOUT,NSA,03-10-24 10-25-31:\"USER LOGGED
Value
Up to 20 case-insensitive alphanumeric characters
Up to 20 case-sensitive characters. You must include at
least two non-alphabetic and one special character (other
than a letter, number, comma, colon, or semicolon). For
case-sensitive passwords, enclose the <pid> in quotes.
The access level for the user specified by the <uid>
TP-SSU 03-10-24 10:28:24
"IMC:NA,USRADD,NSA,03-10-24 10-28-24:\"USER HAS BEEN
Description
097-58001-02 Revision G – April 2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edge clock 1100Timeprovider 1000Timeprovider 1100