Symmetricom EDGE CLOCK 1000 User Manual page 169

Edge clock
Table of Contents

Advertisement

Table 6-5. Event Codes (Continued)
Keyword
Event ID
Description
ISEQ
Indicates that the CRC
of two Istate images
stored on separate
modules are equal
LOGECHO
The system echoes
the login or logout
events
LOGIN
A user has logged in
to the system
LOGOUT
A user has logged out
of the system
PIDCHG
A user's password has
changed in the
database
RESET
The IMC has been
reset by user
command
SIDCHG
The source ID has
changed in the
database
UIDCHG
A user's name has
changed in the
database
USRADD
A user has been
added to the database
USRDEL
A user has been
deleted from the
database
XFERFAIL
Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the redundant
IOC was not
successful
097-58001-02 Revision G – April 2008
Chapter 6 Maintaining and Troubleshooting the TimeProvider
AID
Default Value/
TYPE
Keyword
EQPT
n/a
EQPT
ENABLE
EQPT
n/a
EQPT
n/a
EQPT
pid
EQPT
n/a
EQPT
n/a
EQPT
uid
EQPT
uid
pid
uap
EQPT
uid
EQPT
n/a
Troubleshooting the TimeProvider
Description of Values
n/a
ENABLE – The login/logout
events are echoed
DISABLE – The login/logout
events are not echoed
n/a
n/a
User Password – up to 20
alphanumeric characters
n/a
20-character name used to
identify the network element
User Identification – up to 20
characters
uid – assigned user name
pid – assigned user password
uap – assigned user access
level
uid – username
n/a
TimeProvider User's Guide 169