Symmetricom EDGE CLOCK 1000 User Manual page 133

Edge clock
Table of Contents

Advertisement

This command has a default access level of USER.
ALL (or null)
SYS
IMC
IOCm (m = 1 | 2)
PRS
INPp (p = 1 | 2)
OUTg (g = A | B | C | D)
Normal Response Format
<cr><lf><lf>
^^^sid^date^time<cr><lf>
M^<ctag>^COMPLD
^^^"<aid>,aidtype:ntfcncde,condtype,srveff,ocrdat,ocrtim
<:condscr>"<cr><lf>*
;
where * indicates zero or more of the preceding element
Value
<aid>
aidtype
ntfcncde
condtype
srveff
ocrdat
ocrtim
condscr
Sample Command
RTRV-ALM:::TS1000;
This command causes the TimeProvider to return all current alarms.
097-58001-02 Revision G – April 2008
<aid>
Description
Access identifiers
Access identifier
Access identifier type
EQPT – alarm associated with operation of the system
T1 – alarm associated with inputs or outputs
Notification code:
MN – Minor alarm
MJ – Major alarm
CR – Critical alarm
Condition type – keyword associated with the command
Service affecting indicator
Occurrence date of the alarm
Occurrence time of the alarm
Optional condition description – text string enclosed in quotation
marks
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Description
TimeProvider User's Guide 133