WorkCentre Pro 423/428

2.4.9.3 NVM Settings

Chain Function
6
40
Maximum number of pages Transmitted
6
41
Minimum Guaranteed Read Time for Accumulated
Document (DADF)
6
42
Maximum Number of Copies Accumulated
6
43
Minimum Guaranteed Read Time for Accumulated
Document (PLATEN)
6
60
Image Section ROS Quantity of Light (600dpi)HANA
Text/Text Photo
6
61
Image Section ROS Quantity of Light (600dpi)HANA Photo
6
62
Image Section ROS Quantity of Light (400dpi)HANA
6
63
Quantity of Light after Feedback Control (600dpi)
6
64
Quantity of Light after Feedback Control (400dpi)
6
65
Coefficient for Controlling Light of Quantity
6
80
LASER SIDE REGI Adjustment (600dpi)ALL TRAY
6
81
LASER SIDE REGI Adjustment (600dpi)TRAY1
6
82
LASER SIDE REGI Adjustment (600dpi)TRAY2
6
83
LASER SIDE REGI Adjustment (600dpi)TRAY3
6
84
LASER SIDE REGI Adjustment (600dpi)TRAY4
6
85
LASER SIDE REGI Adjustment (600dpi)MSI
6
86
LASER SIDE REGI Adjustment (600dpi)DUP ALL TRAY
6
87
LASER SIDE REGI Adjustment (600dpi)DUP TRAY1
6
88
LASER SIDE REGI Adjustment (600dpi)DUP TRAY2
6
89
LASER SIDE REGI Adjustment (600dpi)DUP TRAY3
6
90
LASER SIDE REGI Adjustment (600dpi)DUP TRAY4
6
91
Edge erase in fast scan (left)
6
92
Edge erase in fast scan (right)
6
93
Edge erase in slow scan (LE)
6
94
Trail edge image cut amount adj.
6
95
MSI image loss adjustment amount
6
96
LASER SIDE REGI Adj. (600dpi) 90 degree Rotation
6
97
LASER SIDE REGI Adj. (600dpi) 180 degree Rotation
6
98
LASER SIDE REGI Adj. (600dpi) 270 degree Rotation
Item
Min. value
1
1
1
1
31
31
31
-
-
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
-26mm
0
-4mm
1
1
1
2-150
03/02
Default
Max. value
Amount of
Change
999
999
1 sheet
4
20
1 sec
999
999
1 sheet
4
20
1 sec
93
124
87
124
93
124
40
-
46
-
5
99
50
99
0.0423mm
50
99
50
99
50
99
50
99
50
99
50
99
50
99
50
99
50
99
50
99
47
94
0.0423mm
47
94
0.0423mm
47
94
0.0423mm
50
119
0.26mm
0mm
+31mm
130
189
0.0423mm
+1.5mm
+4mm
50
99
50
99
50
99
CHAPTER 2 TROUBLESHOOTING
How to use the Diagnostic C/E Mode
Adjustment
Remarks
This value is stored in M/F MAIN PWB NVM.
Auto rewritten after print. The value in Ch6-60
is copied at NVM initialization and DRUM
replacement.
Auto rewritten after print. The value in Ch6-60
is copied at NVM initialization and DRUM
replacement.
As the adj. value is increased, the image
shifts close to the FRONT.