3. Remove the Holder. (Figure-2)
1) Remove the screw.
2) Remove the Stopper.
3) Remove the screw.
4) Remove the Holder.
5) Disconnect the connector.
6) Release the Clamp.
(Figure-2) j0hn4318
4. Remove the Lamp Wire Harness. (Figure-3)
1) Turn over the Full Rate Carriage.
2) Remove the screw.
3) Remove the Guide.
4) Remove the Lamp Wire Harness.
WorkCentre Pro 432/428
(Figure-3) j0hn4319
Installation
Procedure
1. Perform the removal steps in reverse order.
2. After installation, adjust the position and parallelism
of the Full Rate Carriage. (ADJ 3.4.2)
03/02
4-15
CHAPTER 4 DISASSEMBLY/ASSEMBLY AND ADJUSTMENT
REP 3.5.1 Platen Cushion
Ref. PL PL3.5
Removal
On printer or Fax-equipped machines, ensure that
outstanding jobs have cleared before servicing or
interrupting the power to the machine as follows:.
• FAX equipped machines: Ensure that the "Job in
Memory" indicator on the control panel goes out.
Press "Job Status:Stop" button and confirm that the
job has cleared from the "Current Jobs" folder.
• Printer machines: Ensure that "Ready to print or
fax" is indicated on the printer control panel.
WARNING
Switch off the machine and disconnect the
power cord.
Note
The Platen Cushion is affixed with double-
sided adhesive tape.
Procedure
1. Peel off the Platen Cushion. (Figure-1)
1) Peel off the Platen Cushion.
(Figure-1) j0hn4320