Chain-
Description
Link
116-332
Invalid Log control
(N6-51)
information
116-333
LocalTalk related system
(N9-42)
call error
116-334
ESS Standard ROM Flash
(N6-30)
Fail
116-335
HD fault detected by MFIO
(N1-41)
116-336
HD fault detected by
(N1-41)
Redirector
116-337
Job template storage error
(N1-41)
on local HD
116-340
Short of page memory,
(N6-50)
input buffer, or work area.
Task activation failure due
to Malloc error or other.
116-341
ROM DIMM version
(N6-40)
mismatch
116-342
Critical error detected by JT
(N9-49)
monitor
116-343
MF-SYS communication
(N9-50)
error detected by JT monitor
116-344
Critical error detected by
(N9-51)
MFIO
LCD display
Job log
Corrective Action
Ready to print
1.Remove HDD, turn
(***-***)
the power ON/OFF,
then reinstall HDD
and power ON.
2.Execute HDD Diag
(DC355).
3.Replace ESS
PWB.
Ready to print
1.Reinstall the ESS
(***-***)
software.
2.Replace ESS
PWB.
Ready to print
(***-***)
Ready to print
1.HDD Format
(***-***)
2.Replace HDD.
3.Replace P-ESS
Board.
Ready to print
1.HDD Format
(***-***)
2.Replace HDD.
3.Replace P-ESS
Board.
Ready to print
1.HDD Format
(***-***)
2.Replace HDD.
3.Replace P-ESS
Board.
Ready to print
1. Add memory.
(***-***)
2. Extract the
PostScript option.
Ready to print
(***-***)
Ready to print
1.Power OFF/ON.
(***-***)
2.Replace ESS
PWB.
Ready to print
(***-***)
Ready to print
1.Power OFF/ON.
(***-***)
2.Replace ESS
PWB.
2-64
03/02
Chain-
Description
Link
116-345
Token Ring Control IC
(N1-60)
access error
116-346
Critical error detected by
(N9-53)
Formatter
116-347
LocalTalk board failure
(N1-30)
116-348
Critical error detected by
(N9-54)
Redirector
116-349
Pfile function call error by
(N9-26)
SIF
116-350
AppleTalk general critical
(N9-43)
error
116-351
EtherTalk related critical
(N9-41)
error
116-352
NetWare related critical
(N9-45)
error
116-353
lpd related critical error
(N9-44)
116-355
SNMP Agent related critical
(N9-48)
error
116-356
EWS related critical error
(N9-60)
116-357
PS Fatal System error
(N9-20)
CHAPTER 2 TROUBLESHOOTING
2.3 Level 2 Troubleshooting
LCD display
Job log
Corrective Action
Ready to print
(***-***)
Ready to print
1.Power OFF/ON
(***-***)
2.Replace ESS
PWB.
Ready to print
(***-***)
Ready to print
1.Power OFF/ON
(***-***)
2.Replace ESS
PWB.
Ready to print
Replace ESS PWB.
(***-***)
Ready to print
1.Reinstall the ESS
(***-***)
software.
2.Replace ESS
PWB.
Ready to print
1. Reinstall the ESS
(***-***)
software.
2.Replace ESS
PWB.
Ready to print
1. Reinstall the ESS
(***-***)
software.
2.Replace ESS
PWB.
Ready to print
1. Reinstall the ESS
(***-***)
software.
2.Replace ESS
PWB.
Ready to print
1. Reinstall the ESS
(***-***)
software.
2. Replace ESS
PWB.
Ready to print
1. Reinstall the ESS
(***-***)
software.
2.Replace ESS
PWB.
Ready to print
1.Replace ESS
(***-***)
PWB.
2.Collect data.

Hide quick links: