Xerox WorkCentre Pro 423 Service Manual page 86

Hide thumbs Also See for WorkCentre Pro 423:
Table of Contents

Advertisement

WorkCentre Pro 423/428
X Code
Internal
Error Description
Code
X3-70
0892
Other wrong procedures (ISDN)
X3-70
0893
Other interworking class (ISDN)
X3-73
0804
Call requests beyond available
resources
X3-73
0805
Call status mismatch detected
X3-73
0807
Not used (An error which could
not be recognized by ICM
occurred.)
X3-74
0823
UA response is detected in TEI
set state, multi-frame set state
and time recover state.
Equivalent to Toki
EM_DATA_LINK ( 88C5 )
X3-74
0824
TEI control task received ID
reject message which includes
error Ai at waiting state.
(equivalent to Toki EM_TEI_GET
(88C3) )
X3-74
0825
TEI control task received ID set
message which includes the
same value as the present TEI.
equivalent Toki EM_TEI_GET
(88C3)
X3-74
0826
TEI control task received TEI ID
release message. equivalent to
Toki EM_TEI_REL (88C4)
X3-74
0827
TEI control task sent ID request
N202 times at waiting state, but
failed because it could not
receive ID set message.
equivalent to Toki EM_TEI_GET
(88C3)
X3-74
0828
CP68302 transmitter channel
error. Detected error in TXE bit of
SCCE register.
2-54
03/02
Corrective Action
System data check.
Check/replace G4/ICM PWB.
System data check.
Check/replace G4/ICM PWB.
System data check.
Check network and line.
Check/replace G4/ICM PWB.
Check the line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check/replace G4/ICM PWB.
X Code
Internal
Error Description
Code
X3-74
0829
In HDLC channel, incomplete
buffer was received. Error
detected in TXE bit of SCCE
register.
X3-74
88C3
An illegal event was received.
X3-74
88C4
T.317 time out (Initialization
procedure failure)
X3-75
0848
Received initialization message.
X4-43
0271
Forward job terminated due to
illegal event from OA board.
CHAPTER 2 TROUBLESHOOTING
2.3 Level 2 Troubleshooting
Corrective Action
Check/replace G4/ICM PWB.
Replace G4/ICM PWB.
Replace G4/ICM PWB ROM.
System error.
Replace MAIN or G4/ICM PWB.
Replace G4/ICM PWB ROM.
Check the line.
Check/replace G4/ICM PWB.
Check/replace OA board.