Xerox WorkCentre Pro 423 Service Manual page 46

Hide thumbs Also See for WorkCentre Pro 423:
Table of Contents

Advertisement

WorkCentre Pro 423/428
V Code
Internal
Description
code
V1-05
83A5
Illegal communication
command received by
Comm handler
V1-05
83A6
Protocol trace acquisition
failure
V1-05
83A7
Abnormal return value from
DTMF checker
V1-05
83A8
Job type abnormal after
DTMF procedure
V1-05
83A9
Abnormal return value from
host DTMF related function
V1-06
83B0
Illegal channel number
received by G3 module
handler
V1-06
83B1
No response from G3 at
system boot
V1-06
83B2
Command interface from
M/F MAIN PWB to G3 is
busy at system boot
V1-06
83B3
Command interface from G3
to M/F MAIN PWB not
active at system boot
V1-06
83B4
Illegal interrupt detected by
G3 module handler
V1-06
83B5
Illegal command received by
G3 module handler
V1-06
83B6
Illegal ID received by G3
module handler
V1-06
83B7
Idle notification not received
from G3M
03/02
Corrective Action
Check/replace M/F MAIN PWB,
NCU, G4M, G4/ICM, motherboard,
PAGE MEMORY, MMB, and
HANDSET.
Check/replace M/F MAIN PWB,
G3M, G4M, and G4/ICM.
Check M/F MAIN PWB and MMB.
Check M/F MAIN PWB and MMB.
S/W bug in the process monitor.
Check M/F MAIN PWB and MMB.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
2-14
V Code
Internal
code
V1-07
83C0
Illegal channel number
received by G3 channel
handler
V1-07
83C1
Illegal command received by
G3 channel handler
V1-07
83C2
G3 channel event posting
failure
V1-08
83D0
Illegal channel number
received by PSTN handler
V1-08
83D1
Illegal command received by
PSTN handler
V1-08
83D2
PSTN channel event posting
failure
V1-09
83E0
No response from G4 at
system boot
V1-09
83E1
Illegal channel number
received by G4 module
handler
V1-09
83E2
Illegal command received by
G4 module handler
V1-09
83E3
Command interface from
M/F MAIN PWB to G4 is
busy
V1-09
83E4
Illegal interrupt detected by
G4 module handler
V1-09
83E5
Illegal ID received by G4
module handler
V1-09
83E6
Illegal reference number
received by G4 module
handler from G4 module
CHAPTER 2 TROUBLESHOOTING
2.3 Level 2 Troubleshooting
Description
Corrective Action
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check M/F MAIN PWB and G3M
board for connections. Replace
M/F MAIN PWB or G3M board.
Check/replace M/F MAIN PWB,
NCU, motherboard, PAGE
MEMORY, and MMB.
Check/replace M/F MAIN PWB,
NCU, motherboard, PAGE
MEMORY, and MMB.
Check/replace M/F MAIN PWB,
NCU, motherboard, PAGE
MEMORY, and MMB.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.
Check M/F MAIN PWB and G4M
board for connections. Replace
M/F MAIN PWB or G4M board.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre pro 428

Table of Contents