Technical Data - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Modules Booksize
4.7 Basic Line Modules with internal air cooling
4.7.8

Technical data

Table 4- 50
Technical data: Basic Line Modules
Internal air cooling
Rated power
Infeed
1)
Rated power S1 duty
Infeed power S6 duty (40 %)
Peak infeed power
Braking power
Continuous power
Peak power
Supply voltages
Line voltage
Line frequency
Electronics power supply
DC link voltage
Overvoltage trip
Undervoltage trip
3)
Input currents
Rated input current:
for AC 400 V
input current:
for AC 380 V / AC 480 V
for AC 400 V; S6 duty (40 %)
for AC 400 V; peak current
DC link currents
Rated DC link current:
for 600 V
DC link current:
for 540 V
for 600 V DC; S6 duty (40 %)
for 600 V DC; peak current
Current carrying capacity
DC link busbars
Reinforced DC link busbars
24 V DC busbars
Electronics current drawn at 24 V DC
Total power loss
(including electronics losses, see Power
loss tables (Page 756))
DC link capacitance
Basic Line Module
Drive line-up, max.
Power factor
4)
Circuit breaker
(IEC 60947 and UL)
Rated short-circuit current
SCCR
5)
238
6SL3130-
1TE22-0AA0
kW
20
kW (P
)
20
n
kW (P
)
26
S6
kW (P
)
60
max
kW (P
)
5
n
kW (P
)
40
max
V
3 AC 380 ... 480 ±10 % (- 15 % < 1 min)
ACrms
Hz
47 ... 63
V
24 (20.4 ... 28.8)
DC
V
510 ... 720
DC
V
820 ± 2 %
DC
V
360 ± 2 %
DC
A
33
AC
A
35 / 28
AC
43
A
AC
A
100
AC
A
33.5
DC
A
37
DC
A
43
DC
A
100
DC
A
100
DC
A
150
DC
A
20
DC
A
1
DC
W
144
μF
940
μF
20000
cos φ
0.98
See Chapter Overcurrent protection using fuses and circuit break-
ers (Page 51)
kA
65
1TE24-0AA0
1TE31-0AA0
40
100
40
100
52
130
120
175
10
-
80
-
2)
66
166
70 / 55
172 / 138
86
216
199
290
67
167
48
185
87
217
200
292
200
200
--
--
20
20
1.4
2.0
283.6
628
1880
4100
20000
50000
0.98
0.98
65
65
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents