Comparison Of Drive-Cliq Signal Cables - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet design and EMC Booksize
12.7 Connection systems
12.7.1.5

Comparison of DRIVE-CLiQ signal cables

DRIVE-CLiQ signal cables are designed for various applications. The following table
provides an overview of the most important properties.
Table 12- 13 Properties of DRIVE-CLiQ signal cables
DRIVE-CLiQ signal cable
Approvals
cURus or UR/CSA
1)
In conformance with RoHS
Rated voltage V
/V in ac-
0
cordance with EN 50395
Test voltage, rms
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. travel velocity
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
The UR/CSA file number is stamped on the cable sheath.
1)
Acceleration characteristics, refer below
2)
708
DRIVE-CLiQ
Yes
Yes
30 V
500 V
-20 ... +80 °C
-
45 N/mm
2
_
50 mm
-
-
-
-
-
CFC/silicon-free
EN 60811-2-1
PVC
Gray RAL 7032
EN 60332-1-1 to 1-3
DRIVE-CLiQ
MOTION-CONNECT 500
Yes
Yes
30 V
500 V
-20 ... +80 °C
0 ... 60 °C
80 N/mm
2
30 N/mm
2
35 mm
125 mm
30 °/m absolute
100000
30 m/min
2 m/s
2
CFC/silicon-free
EN 60811-2-1
(mineral oil only)
PVC
DESINA color green
RAL 6018
EN 60332-1-1 to 1-3
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
DRIVE-CLiQ
MOTION-CONNECT 800PLUS
Yes
Yes
30 V
500 V
-20 ... +80 °C
-20 ... +60 °C
50 N/mm
2
20 N/mm
2
35 mm
75 mm
30 °/m absolute
10 million
300 m/min
50 m/s
(3 m distance moved
2
through)
2)
CFC/halogen/silicone-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color green, RAL 6018
EN 60332-1-1 to 1-3
Booksize Power Units

Hide quick links:

Advertisement

Table of Contents
loading