14.1 Replacing the fan
14.1.4

Replacing the fan on the Control Supply Module

Spare part fan (article number. 6SL3160-0AB00-0AA0)
Danger of death when live parts with several supply circuits are touched
Death or serious injury can result when live parts are touched.
• Switch off all of the supply circuits before you start any work.
Removing the fan
1. Remove the component from the drive line-up.
2. Remove the 6 screws (Torx T10) from the housing cover
and open the component.
794
WARNING
3. Release and withdraw the connector.
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8