Line connection and line-side power components
3.8 Line reactors
3.8.4.4

Technical data

Together with the HFD line reactor, an external resistor must be used for damping purposes
(refer to Chapter Wiring with the HFD line reactor (Page 103)).
Table 3- 16
Technical data for HFD damping resistors
Article No.
Rated power [W]
Connection cable [m],
included in scope of delivery
Connection
Weight [kg]
Degree of protection to
IEC 60529
UL file
Ambient temperature [°C]
Dimensions (W x H x D)
[mm]
The 300 W damping resistor can be used for HFD applications if the following is true after a heat run when all axes are
1)
shut down in a regulated way:
- After an operating period of over two hours, the surface temperature of resistor 6SN1113-1AA00-0DA0 must not ex-
ceed 150° C.
- This heat run must be repeated if the hardware configuration, e.g. motor cable lengths, is changed!
Preferred type
2)
Alternatively possible
3)
102
6SN1113-1AA00-0DA.
1)
300
3
3 x 1.5 mm
2
1.45
IP54
E-228809
0 ... 55
80 x 210 x 53
6SL3100-1BE21-3AA.
2)
800
5
4 x 1.5 mm
2
5.5
IP51
E-212934
277 x 552 x 75
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
6SL3100-1BE22-5AA.
3)
1500
5
4 x 1.5 mm
2
5.6
IP20
E-192450
193 x 410 x 240