11.1 Shield connecting plates for power supply and motor cables
Example 2: 200 mm wide component with internal air cooling
Required tools:
● Torx screwdriver T25 for protective conductor connection (Torx slot)
● (Torque) wrench M8 for power cables
● Flat-bladed screwdriver for hose clamp
Table 11- 9
Connecting power cables for a 200 mm wide component using internal air cooling as an example
1. Release and open the cover of the
terminal strip.
4. Adapt a restrictor collar (using a
suitable tool) for the touch protection.
618
2. Remove the M8 nuts.
5. Push on the reduction collar.
3. Attach the protective conductor and
the power cable.
Tightening torque: 13 Nm
6. Tighten the hose clamp at the shield
connecting plate.
Booksize Power Units