Maximum Cable Lengths - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet design and EMC Booksize
12.7 Connection systems
12.7.4

Maximum cable lengths

The table below provides an overview of the maximum permissible cable lengths for signal
and supply cables, power cables, and DC link cables.
Note
Total cable lengths for Line Modules
For data regarding maximum total cable lengths of Line Modules and general conditions for
maintaining the corresponding radio interference suppression category, see Chapter
Combination options of Line Modules with line reactors and line filters (Page 135).
Table 12- 21 Maximum cable lengths
Type
24 V DC power supply cables
24 V signal cables
DRIVE-CLiQ signal cables MC500 (RJ45)
DRIVE-CLiQ signal cables MC500 (M12)
DRIVE-CLiQ signal cables MC800PLUS (RJ45)
DRIVE-CLiQ signal cables MC800PLUS (M12)
DC link, including extensions
Power cable between line filter and line reactor
Power cable between line reactor and Line Module
Power cable between
motor and Motor Module up to I
Power cable between
motor and Motor Module I
Power cable between
motor and Motor Module I
Power cable between Braking Module and braking resistor
For longer lengths, users must connect suitable protective circuitry in order to provide surge voltage protection (refer to
1)
Chapter "24 V DC supply/surge voltage protection").
To comply with EMC limit values, shielded cables (preferably MOTION-CONNECT cables) must be used.
2)
716
= 9 A
n
= 18 A
n
≥ 30 A
n
Maximum length [m]
30
1)
30
1)
100
30
75
30
10
10 (shielded/unshielded)
10 (shielded/unshielded)
50 (shielded)
75 (unshielded)
70 (shielded)
100 (unshielded)
100 (shielded)
150 (unshielded)
10
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
2)
2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents