Motor Modules in booksize C/D-type format
3.2 Motor Modules with internal air cooling
3.2.7
Technical data
3.2.7.1
Single Motor Modules
Table 3- 5
Technical data of Single Motor Modules in booksize C-type format (18 to 30 A)
C-type
Output current (at 600 V DC)
Rated current (l
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (l
)
max
Output voltage
Output frequency
DC link current
1)
Rated current I
d rated
DC link voltage (up to 2000 m above sea level)
DC link capacitance
Overvoltage trip
Undervoltage trip
2)
Electronics power supply
Electronics current drawn
at 24 V DC
Current carrying capacity
DC link busbars
Reinforced DC link busbars
24 V DC busbars
Unit rating
3)
based on I
(600 V DC; 4 kHz)
rated
based on I
H
Typical power loss
See also Power losses of the components
(Page 116)
Max. pulse frequency
Without derating
With derating
Max. ambient temperature
without derating
with derating
Sound pressure level
Cooling method
Cooling air requirement
56
) 40%
s6
6SL3120-
1TE21-8AC.
A
18
AC
A
15.3
AC
A
24
AC
A
36
AC
V
AC
Hz
A
22
DC
V
DC
μF
220
V
DC
V
DC
V
DC
A
0.75
DC
A
DC
A
DC
A
DC
kW
9.7
kW
8.2
W
140
kHz
kHz
°C
°C
dB(A)
m
/h
33.3
3
1TE23-0AC.
30
25.5
40
56
0 ... 0.717 x DC link voltage
(0 ... 480 V at 670 V DC)
0 ... 550
36
510 ... 720
705
820 ± 2 %
380 ± 2 %
24 (20.4 ... 28.8)
0.80
100
150
20
16
13.7
263
4
16
40
55
< 60
Internal fan
56
Power Units in Booksize C/D-Type Format
Manual, 01/2017, 6SL3097-4AC20-0BP1