Siemens SINAMICS S120 Manual page 431

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Mounting
External heat sink (air or liquid)
Threaded bolts M6
Heat-conducting foil
Cold plate
Washer
Spring washer
M6 nut
Figure 6-71
Mounting a Motor Module with cold plate on an external heat sink (example: 3 A Motor Module)
Tightening torques:
1. Firstly, tighten the nuts by hand.
Tightening torque: 0.5 Nm
2. Then tighten the nuts.
Tightening torque: 10 Nm
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Motor Modules Booksize
6.4 Motor Modules with cold plate
431