Technical Specifications - Siemens SINAMICS S120 Equipment Manual

Chassis power units liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

1.3

Technical specifications

Technical specifications
Unless explicitly specified otherwise, the following technical specifications are valid for all the
following components of the SINAMICS S120 Liquid Cooled drive system.
Table 1-1
General technical specifications
Electrical data
Line connection voltage
Line frequency
Output voltage
Output frequency
Electronic power supply
Short-circuit current rating SCCR in accordance
with UL508C (up to 600 V)
Radio interference suppression
Overvoltage category
Mechanical data
Vibratory load
Transportation
1
Operation
Shock stressing
Transportation
1
Operation
Environmental requirements
Degree of protection
Protection Class
Cooling method according to
EN 60146-1-1:1993
in packaging for transportation
1
Chassis Power Units Liquid Cooled
SINAMICS S120 Equipment Manual, Edition 12/2007, 6SL3097-2AM00-0BP4
380 V 3 AC –10 % to 480 V 3 AC +10 % (-15 % < 1 min)
500 V 3 AC –10 % to 690 V 3 AC +10 % (-15 % < 1 min)
47 Hz to 63 Hz
0 to line connection voltage (depending on the infeed type)
0 Hz to 300 Hz
24 VDC (20.4 V - 28.8 V)
1.1 kW - 447 kW:
448 kW - 671 kW:
672 kW - 1193 kW:
>1194 kW:
Category C3 (environment 2) to EN 61800-3
Class III to EN 60664-1
EN 60721-3-2, class 2M2
Test values in accordance with EN 60068-2-6 test Fc:
10 to 58 Hz with constant deflection = 0.075 mm
58 to 200 Hz with constant acceleration = 9.81 m/s² (1 g)
EN 60721-3-2, class 2M2
Test values in accordance with EN 60068-2-27 test Ea:
98 m/s² (10 g) / 20 ms
IP00 acc. to EN 60529
Class I (with protective conductor system) and class III (PELV) to
EN 61800-5-1
Power Modules, Basic Line Modules, Active Line Modules,
Motor Modules: WE
W: Liquid cooling
E: Forced cooling, drive unit outside the device
Active Interface Modules: AF
A: Air cooling
F: Forced cooling, drive unit inside the device
Line reactors, sine-wave filters, motor reactors, dv/dt filters with
Voltage Peak Limiter: AN
A: Air cooling
N: Natural cooling (convection)
1.3 Technical specifications
65 kA
84 kA
170 kA
200 kA