Danger to life due to electric shock in the event of voltage flashovers at the temperature
sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Use temperature sensors that comply with the specifications relating to protective
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
4.5.2.4

X24 24 V terminal adapter

Table 4- 27
Type: Screw terminal 5 (Page 730)
The 24 V terminal adapter is included in the scope of supply.
4.5.2.5

X200-X202 DRIVE-CLiQ interfaces

Table 4- 28
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking cover (50 pcs.) Article number: 6SL3066-4CA00-0AA0
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
WARNING
separation.
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal
Module TM120.
X24: 24 V terminal adapter
Terminal
+
M
X200-X202: DRIVE-CLiQ interfaces
PIN
1
2
3
4
5
6
7
8
A
B
Designation
24 V power supply 24 V DC supply voltage
Ground
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+(24 V)
M (0 V)
Line Modules Booksize
4.5 Active Line Modules with cold plate
Technical data
Electronics ground
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
24 V power supply
Electronics ground