Line Modules Booksize
4.11 Smart Line Modules with cold plate
Help with the mechanical control cabinet design is available from:
Siemens AG
Digital Factory, DF MC MF - WKC AS
TCCCC (Technical Competence Center Cabinets Chemnitz)
Postfach 1124
09070 Chemnitz
e mail: cc.cabinetcooling.aud@siemens.com
Properties of the heat sink
We recommend using AlMgSi 0.5 as the heat sink material.
The roughness of the external heat sink surface should be at least Rz 16 and the contact
surface between the heat sink and cold plate should have an evenness of 0.2 mm.
Note
Machine manufacturers can adapt the heat sink version to their special requirements. The
specified rated data for the Power Modules can only be achieved if the power losses can be
dissipated by the external heat sink under the specified general conditions.
NOTICE
Damage to the cold plate caused by incorrect mounting
The threaded bolts can damage the cold plate when it is being mounted.
• Do not damage the cold plate.
4.11.9

Technical data

Table 4- 91
Technical data for Smart Line Modules with cold plate cooling
Rated power
Infeed
1)
Rated power S1 duty
Infeed power S6 duty (40 %)
Peak infeed power
Regenerative feedback
Continuous regenerative power
Peak regenerative power
Supply voltages
Line voltage
Line frequency
Electronics power supply
DC link voltage
Overvoltage trip
Undervoltage trip
324
6SL3136-
6AE15-0AA.
kW
5
kW (P
)
5
n
kW (P
)
6.5
S6
kW (P
)
10
max
kW
5
kW
10
V
3 AC 380 ... 480 ± 10 % (-15 % < 1 min)
AC
Hz
47 ... 63
V
24 (20.4 ... 28.8)
DC
V
510 ... 720
DC
V
820 ± 2 %
DC
V
360 ± 2 %
DC
6AE21-0AA.
10
10
13
20
10
20
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8