REP 5.1.5 Fuser Pressure Roll

Parts List on PL 5.1
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
The Fuser and Exit Transport are hot. Do not work on them until they are cool enough.
Do not touch the glass part of the Fuser Lamp unless you are are wearing gloves.
1.
Remove the Fuser Roll (REP 5.1.4).
2.
Remove the Bushings (Figure 1).
Bushings
Figure 1 Removing the Bushings
Repairs and Adjustments
REP 5.1.5
WARNING
WARNING
CAUTION
3.
Remove the Fuser Pressure Roll (Figure 2).
1 Remove the Levers.
2 Remove the Spring Mount Assemblies.
3 Remove the Fuser Pressure Roll.
Figure 2 Removing the Fuser Pressure Roll
Replacement
Do not touch the glass part of the Fuser Lamp unless you are wearing gloves.
NOTE: When installing the Fuser Roll, see REP 5.1.4.
1.
To install, do the removal steps in reverse order.
July, 2007
4-38
Levers
Fuser Pressure Roll
Spring Mount Assemblies
CAUTION
Initial Issue