REP 10.6.1 Exposure Lamp
Parts List on PL 10.6
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
1.
Remove the following parts:
•
Platen Cover (PL 10.1)
•
Control Panel (REP 8.3.1)
2.
Remove the IIT Upper Cover (REP 10.2.1).
3.
Remove the Inverter PWB Bracket 2 (Figure 1).
1 Remove the screw.
2 Remove the Inverter PWB Bracket 2.
Initial Issue
WorkCentre 5020
WARNING
Figure 1
4.
Disconnect the connector (Figure 2).
1 Release the wire harness from the clamp.
2 Disconnect the connector.
July, 2007
4-75
Figure 2
Repairs and Adjustments
REP 10.6.1