Appendix G: Peripherals
Configuration
The Ethernet module should configure on the data bus automatically. If not, refer to
Connection to the Intellibus on page 26. The Ethernet module uses DHCP to configure
automatically onto the local area network. If manual setup is required, refer to [56.3.3].
Jumper headers
P3: tamper bypass
Diagnostics
Once powered up the following LEDs can be used to check the status of the module.
LEDs
Network: Ethernet network connection (on when connected)
Ethernet:
Active Ethernet communications (flashing)
Intellibus: Panel connection good (short flash every second)
Specifications
Service temperature
Storage temperature
Humidity
Product weight (PCB)
Dimensions (PCB)
Nominal Supply Voltage
Typical Current
Maximum Current
Network Compatibility
Encryption
Compliance
This product is suitable for use in systems designed to comply with EN50131-
1:2006+A1:2009 and PD6662: 2010. This module complies with the requirements of
EN50136-1-1:1998+A2:2008.
Security Grade – 4
Environmental Class – II
Alarm Transmission System – ATS5=D3, M3, T4, S2, I3
Prevention of substation, according to EN50136-1, is achieved using encryption of account
number and messages to and from the ARC combined with the ability of the CIE to detect
unauthorised removal and addition of devices to the databus.
232
-10 deg to +40 deg C
-10 deg to +60 deg C
25% to 55%
50g
L68mm x W80mm x D18mm
15V d.c.
110mA
135mA
100/10 base-T
AES128 Bit
Galaxy Flex Installer Manual