Honeywell Galaxy Flex V3 Series Installer Manual page 202

Table of Contents

Advertisement

Appendix B: SIA & contact ID event codes Galaxy Flex Installer Manual
Ev
SIA Event
Description
CL
Closing Report
CP
Auto. Closing
CR
Recent Close
CT
Late to Open
D - Access
DD
Access Denied
DF
Door Forced
DG
Access Granted
DK
Access Lockout
DK
Access Lockout
DT
Door propped
E - System Trouble
ER
Mod Removed
ET
RF NVM Fail
F - Fire
FA
Fire Alarm
FB
Fire Bypass
FJ
Fire Troub rest
FR
Fire Restoral
FT
Fire Trouble
FU
Fire Unbypass
FV
Fire Confirm
FX
Fire Test
G - Gas (Custom SIA - See Note 2)
GA
Alarm
GB
Bypass
GJ
Trouble Rest
GR
Alarm Restore
GT
Trouble
GU
Unbypass
202
Log
Log Event
Event
Description
FULL SET
Full set
FULL SET
Set by keypad
KSW SET
Keyswitch set
REARM
Re-arm after alarm
RECEN.SET
Previous alarm was within
5 mins of set
TIMEOUT
Entry timeout
Invalid Card
MAX tag unknown
MAX ALARM
Door contact broken
DCM EVENT
Door contact broken
LEGAL CD
Legal code entered
LEGAL CD
ATM code entered
Valid
MAX tag accepted
ILL-CODE
Illegal code entry
REJECT CARD
Illegal MAX tag
FOB REJECT
Illegal Fob
DCM EVENT
Invalid Card Reader Lockout
DOOR PROP
MAX - Door left open
REMOVED
Module Removed
RF MEM!
RF NVM RAM Fail
FIRE+
Fire zone alarm
OMITTED
Fire zone omitted
FORCEOMT+
Force omit after rearm
LOW RES-
Restor zone resistance
HIGH RES-
Restor zone resistance
FIRE-
Fire zone restored
LOW RES+
Low resistance on zone
HIGH RES+
High resistance on zone
FORCE OMT-
Unomitted after rearm
FIRE CONF
2 independent fire alarms
FIRE
Fire zone tested
SOAK TEST
Soak test fire zone act
Note 1
zone in alarm
OMITTED
zone omitted
FORCEOMT+
Force omit after rearm
LOW RES-
Restor zone resistance
HIGH RES-
Restor zone resistance
Note 1
zone restored
LOW RES+
Low resistance on zone
HIGH RES+
High resistance on zone
FORCE OMT-
Unomitted after rearm
Ev Type Trigger
USER
10.SETTING
EVENT
10.SETTING
ZONE
10.SETTING
EVENT
10.SETTING
EVENT
2.INTRUDER
EVENT
10.SETTING
MOD
17.MAXTAG
MOD
4.SECURITY
17.MAXTAG
MOD
4.SECURITY
USER
16.LOG
USER
16.LOG
USER
17.MAXTAG
USER
16.LOG
USER
17.MAXTAG
ZONE
10.SETTING
USER
16.LOG
10.SETTING
17.MAXTAG
MOD
4.SECURITY
MOD
TAMPER
MOD
TAMPER
ZONE
6.FIRE
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
6.FIRE
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
EVENT
6.FIRE
ZONE
NOT SENT
ZONE
NOT SENT
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
5.CUS ZON
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
Contact
ID Event
401
401
409
463
459
None
421
423
423
462
462
422
421
421
421
421
426
532
333
110
573
573
380
380
110
380
380
573
139
None
None
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy flex 20 v3Galaxy flex 50 v3Galaxy flex 100 v3

Table of Contents