Honeywell Galaxy Flex V3 Series Installer Manual page 147

Table of Contents

Advertisement

Galaxy Flex Installer Manual
User Notify [56.2]
This section defines messages than can be sent directly to an end user's mobile phone.
û
1 = Mobile No 1
û
2 = Mobile No 2
û
3 = Mobile No 3
û
4 = SMS Triggers
û
1 = Intruder
û
2 = Duress
û
3 = Fire
û
4 = Fault
û
5 = Custom Zones
û
6 = Power
7 = Setting
5 = Site ID
Mobile No [56.2.1], [56.2.2] or [56.2.3]
Use these three options to enter three different mobile numbers (22 digits max.) for message
recipients.
SMS Triggers [56.2.4.event]
Use this option to setup the trigger information for any of the event types listed in the menu
structure above.
1=Descriptor
If required you can enter an alternate 16 character description of the
alarm type to help recipient recognition.
2=Mode
Turn the trigger on an off.
3=Phone Sequ.
Define the order in which the three mobile numbers will be used to
transmit the event.
Site ID [56.2.5]
Use this option to enter an ID, which is added to SMS alarm messages to identify the site or
alarm system.
û
1 = Descriptor
û
2 = Mode (0 = Disabled, 1 = Enabled)
û
3 = Phone Sequ.
4 = Groups
Each one of these event options
û
has the same sub-menus options
as 1 = Intruder
Communications [56]