Honeywell Galaxy Flex V3 Series Installer Manual page 143

Table of Contents

Advertisement

Galaxy Flex Installer Manual
1 – as level 0 plus 6 digit accounts.
2 – as level 1 but with event modifiers.
3 – as level 2 but with text descriptions.
Microtech [56.1.1.receiver.path.2.3] (PSTN, GSM)
Microtech [56.1.1.receiver.path.2.2] (GPRS, Ethernet)
Microtech [56.1.1.receiver.path.1.1] (USB)
Microtech format is a protocol that transmits detailed point identification information to a
computer that has the Alarm Monitoring software installed.
The menu structure and programming of the options is identical to the SIA format (see
above).
Contact ID [56.1.1.receiver.path.2.4] (PSTN, GSM)
Contact ID format is a protocol that transmits point identification information to an Alarm
Receiving Centre that is capable of receiving the Galaxy variant of contact ID.
SMS [56.1.1.receiver.path.2.5] (PSTN, GSM)
Use this option to generate and transmit SMS text messages in response to events that occur.
The events will be transmitted as text formatted as per a SIA event message. For plain test
SMS, use the SMS programming under the User Notification section instead.
Autotest [56.1.1.receiver.path.3]
Autotest [56.1.1.receiver.path.2] (USB only)
Use this option to automatically transmit an engineer test to the Monitoring Station at
programmed intervals, to indicate alarm transmission path integrity.
1=Start Time
Enter the time the first engineer test is transmitted. Subsequent engineer
test transmissions are offset by the value assigned in the Intervals option.
2=Intervals*
Sets the period between engineer test transmissions following the Start
Time. The range is 0 to 99 hours.
Notes:
1. If the Test Interval is 0 (default) the Autotest is disabled, even if a
2. To disable Autotest enter 00:00 (default); no transmissions of test
3=Int. Test
(Intelligent Test) Stops the transmission of an automatic test if any other
signal has already been sent during the autotest interval.
4=Account No.† By default this will be the account number programmed in the ARC
Reporting configuration. Enter an alternate account number here if
required.
* In GPRS this is labelled 1=Intervals
Start Time has been assigned.
signals can be sent at midnight.