Galaxy Flex Installer Manual
PA Mode [58.7]
You can programme the PA hotkeys as follows:
1=Instant
The hotkeys activate the PA alarm instantly. This is the default setting.
0=Monitor
Enables the PA hotkeys to be used as a hold-up monitor as described below.
0=Monitor
In this mode the PA hotkeys start a monitor timer (the time period is set using Hotkey Mon
[51.85]). If for any reason the user cannot cancel the timer before the end of the monitoring
period a hold-up alarm is signalled.
To start or stop the monitor timer:
Do one of the following:
Press
and
Type the Monitor code (user 95), and then press ent. (only if this has been enabled
using Hotkey Mon [51.85]).
The keypad indicates that the timer has started and displays the remaining time.
If a specific zone input linked to the monitor function is activated. The system must log the
cancelling against the zone number. The Zone Type is 53 = Monitor.
Show Status [58.8]
Enable this option to allow the set status of the groups to be displayed.
To display group set status, press
F = Fault
R = Ready
S = Set
– = Group not assigned to keypad
Note: This option works when the system is set (keypad blank) or unset (normal banner).
It does not operate in engineer mode.
To show the status of the groups individually, press
To move between each groups, press
To return to the banner display, press
Keypad Groups [58.9]
You can assign each keypad to selected groups. The keypad then responds only to user
codes that have a group common to it and only displays alarm information on the groups
assigned.
at the same time.
2
and
#
STATUS
Groups
and
and
together.
12345678
RRSRSSFS
group block
and
again.
#
or
and
together.
A
B
again.
#
Keypad [58]
159