Timers [65]
The Flex control panel provides programming of timer schedules on a weekly basis. Each
event corresponds to an ON or an OFF time. The state of the schedule is ON or OFF
depending on the last event that was reached.
Timers can be assigned to:
Individual users to disable them
Individual doors to lock them
Individual groups for autoset
Outputs for automatic activation
Note: The ON period is the secure period for a particular schedule when the Autoset and
Lockout features for allocated groups are enabled and users will be unable to gain
access to allocated areas.
Note: Although the following descriptions mention up to 10 schedules, Flex 20 and Flex
50 units are restricted to 2 and 4 schedules respectively.
Weekly Schedule [65.1.n]
(Substitute n for a number between 1 and 10, representing each of ten different schedules)
A weekly schedule consists of a selection of daily time programs for each day of the week.
The state of the weekly schedule is ON or OFF depending on the last event that was
reached. Up to four weekly schedules with 28 time slots are available for programming
depending on panel variant.
The weekly schedules are used to control these panel functions:
Auto setting
Lockout times
User access times
Timer Outputs
Name [65.1.n.1]
A maximum 12 character alpha-numeric name can be entered here for a weekly schedule
Status [65.1.n.2]
The status of each of the timers is shown here whether 0=OFF or 1=ON. To change the
status press
or
, or press
A
B
Events [65.1.n.3]
This option programs the weekly timer events with Day (Mon-Sun) and ON/OFF times.
Note: The number of weekly timer events is dependent on panel variant.
176
to select ON or
1
2
Galaxy Flex Installer Manual
to select OFF.