Galaxy Flex Installer Manual
PSTN Line Fail [56.3.1.1]
The Telecom module continually monitors the telephone line to which it is connected. Use
this option to select the line monitoring conditions that result in a LINE FAIL event being
reported and recorded in the log. The line monitoring capabilities are:
1=Line Volts
0=Disabled
When a line fail occurs the line voltage is monitored for a period determined by the value
programmed in option 51.68. If sufficient line voltage is restored within this period no event
is stored in the event log.
If an alarm occurs during a line fail condition the programmed bell delay for each of the
groups is overridden (refer to Bell Delay [51.02]).
PSTN No. of Rings [56.3.1.2]
This option determines the number of rings before the module answers an incoming call.
The range is 1 to 20 and the default is 4.
PSTN SMS [56.3.1.3]
Use this option if you want to send SMS messages and a GPRS module is not fitted.
1=Centre ID
2=Protocol
3=Password
GSM Line fail [56.3.2.1.1]
This option monitors the availability of the GSM network. If the network is lost for an
extended period, a Line fail condition is generated.
GPRS Encrypt [56.3.2.2.1]
Use this option to enable and disable encryption for each communication option. The default
setting is OFF for each option. For Complaince to En50136-1-1 S2 encryption must be
enabled.
1=Alarm Report
2=SIA Control
3=IP check
GPRS Connection Timeout [56.3.2.2.2]
Use this option to set the GPRS network switching re-check time. If more than one network
is programmed and and network 1 fails, the panel will switch to network 2. After the timeout
(default Enabled) A line fail occurs if the voltage on the telephone line
falls below three volts, or the line is cut.
Enter phone number of the dial-up message centre service.
Select the protocol required by the dial-up message centre service.
Enter a password, if required by the dial-up message centre service.
Controls encryption for the ARC and Secondary alarm reporting to
the ARC.
Controls encryption for communications between the module and
remote computer using the SIA control command protocol.
Controls encryption of communications from the IP Check function.
Communications [56]
149