Ml Magnet Assembly - FujiFilm Fujica AX-1 Repair Manual And Part List

Table of Contents

Advertisement

REASSEMBLY, REPAIR AND ADJUSTMENT
FUJICA AX -1
o
Apply DC 2.5V across lead wires (blue (—) and orange (+)) of the ML
magnet assembly (4 - 65), and make sure that the mirror rises.
o
With the pin (4 -16) held with 8 Bcrew driver, wind up the film advance
lever. Now, move the screw driver away from the pin slowly, and make
sure that a gap is left between the pin and lever.
(Without this gap, the shutter will not be released sometimes.)
o
When a gap exists the shutter is not released,
o
The magnet coil is broken.
o
Strengthen the spring (4 - 70).
5 - 3

ML magnet assembly (4 - 65)

o
Specifications
DC resistance of coil:
Attracting force:
Operating voltage:
o
Attracting force will reduce if any dust is between the iron core and
attracted piece.
o Exercise care for polarity (positive and negative terminals of the coil).
120 ohms
150 grains or more (at the attracted piece
supporting shaft with the spring unhooked)
DC 2.5V (Should be separated by the spring)