DISASSEMBLY
FUJICA AX - 1
2.
Focusing screen (2 - 33)
a.
Remove two screws (2 - 26) from the lens mount side carefully so that the nuts
( 2 - 2 7 ) will not be dropped off.
b.
Remove the cover plate (2 - 24), and pull out the focusing screen (2 - 33).
NOTE:
When installing a focusing screen, hook it on the leaf spring (2 - 34),
and hold down the front side of the focusing screen with the cover
plate ( 2 - 2 4 ) ,
3.
Amplifier assembly (2 - 13)
a.
Remove two screws (2 - 9), and remove the channel plate B (2 - 1 0 ) and rubber
cushion (2 - 1 1 ) .
b.
Remove the holder (2 - 79) by pulling it.
c.
Remove the screw (2 - 78), and remove the printed circuit board (110B2806100).
d.
Remove four screws (2 - 15).
e.
Take out the amplifier assembly (2 -13) together with the prism case assembly
(2 - 20).
- 8 -