REASSEMBLY, REPAIR AND ADJUSTMENT
FUJICA AX - 1
10 - 3 Capacitor (7 - 43)
o
The 1st and 2nd blinds are controlled by electric signals
o
Electrically, 1 msec. time deviation always exists between the
at 1/1000 sec. shutter speed.
o
Mechanically (relationship between magnet and shutter blind), the time
required by the 1st blind in passing the time measuring point differs from
that by the 2nd blind, and time required by the 2nd blind is 1.5 to 1.0
msec. shorter than that by the 1st blind,
o
A delay time provided by a capacitor is added to the actual time provided
by the amplifier by applying the capacitor to the
time difference of the amplifier is balanced with that of the shutter blind.
o
Capacitors of the following capacities are available for this purpose.
0.047
0.068
0.1
0.22
0.33
0.47
- 8 0 -
and
respectively.
and
signals