4.5 Inserting/changing the needles

Fig. 5: Inserting/changing the needles
(1) - Needle holder
(2) - Middle knife
(3) - Screws
To change the needles:
1. Swivel the folding station to the side ( p. 16).
 The needles are freely accessible.
2. Loosen the screws (3) and pull the needles down and out of the needle
18
CAUTION
Risk of injury from sharp parts!
Punctures or cutting possible.
Only change the needles with the machine switched
off.
When changing the needles, NEVER reach into the
area of the middle knife.
NOTICE
Property damage may occur!
When switching to needles with a different thickness, the needle can
be damaged by the hook.
Readjust the needle guard at the hook.
holders (1).
(4) - Needle groove left needle
(5) - Needle groove right needle