Drive Information - Trane TR150 Programming Manual

Hide thumbs Also See for TR150:
Table of Contents

Advertisement

Parameter Lists
Par.
Parameter description
No. #
14-44
d-axis current optimization for IPM
14-5* Environment
14-51
DC-Link Voltage Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-6* Auto Derate
14-61
Function at Inverter Overload
14-63
Min Switch Frequency
Dead Time Compensation Zero Current
14-64
Level
14-65
Speed Derate Dead Time Compensation
14-9* Fault Settings
14-90
Fault Level

5.1.12 15-** Drive Information

Par. No. #
Parameter description
15-0* Operating Data
15-00
Operating hours
15-01
Running hours
15-02
kWh counter
15-03
Power up's
15-04
Over temp's
15-05
Over volt's
15-06
Reset kWh counter
15-07
Reset running hours counter
15-3* Alarm Log
15-30
Alarm log: error code
15-31
Internal fault reason
15-4* Drive Identification
15-40
FC type
15-41
Power section
15-42
Voltage
15-43
Software version
15-44
Ordered typecode
15-45
Actual typecode string
15-46
Drive ordering no
15-48
LCP ID number
15-49
SW ID control card
15-50
SW ID power card
15-51
Drive serial number
15-53
Power card serial number
15-59
CSIV filename
BAS-SVP16B-EN
Programming Guide
Default value
100%
[1] On
[0] Auto
[1] Warning
[0] No Filter
[0] Trip
[2] 2.0 kHz
[0] Disabled
ExpressionLimit
[3] Trip lock
Default value
2-set-up
0 h
All set-ups
0 h
All set-ups
0 kWh
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
0 N/A
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
02/2017 All rights reserved.
2-set-up
Change
Conversion
during
operation
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Change
Conversion
during
index
operation
FALSE
74
FALSE
74
FALSE
75
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
Type
index
0
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
5
Uint8
Uint8
0
Uint16
Uint8
Type
Uint32
Uint32
Uint32
0
Uint32
0
Uint16
0
Uint16
Uint8
Uint8
0
Uint8
0
Int16
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[21]
0
VisStr[21]
0
VisStr[21]
0
VisStr[10]
0
VisStr[20]
VisStr[16]
111
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr170

Table of Contents