Multi-function I/0
5-9-2

Multi-function Output

Selecting the Multi-function Output (n40)
n40
Multi-function Output (MA/MB and MC)
Setting
0 to 7, 10 to 17
range
(see note)
Set Values
Value
Function
0
Fault output
1
Operation in progress
2
Frequency detection
3
Idling
4
Frequency detection 1
5
Frequency detection 2
6
Overtorque being monitored
(NO-contact output)
7
Overtorque being monitored
(NC-contact output)
10
Alarm output
11
Base block in progress
12
RUN mode
13
Inverter ready
14
Fault retry
15
UV in progress
16
Rotating in reverse direction
17
Speed search in progress
The J7AZ incorporates two multi-function output terminals (MA and MB).
Output from these terminals has a variety of functions according to the
application.
Unit of
setting
Note
Do not set values outside the above setting ranges.
ON: Fault output (with protective function working)
ON: Operation in progress (with RUN command input or inverter output)
ON: Frequency detection (with frequency reference coinciding with output
frequency)
ON: Idling (at less than min. output frequency)
ON: Output frequency ≥ frequency detection level (n58)
ON: Output frequency ≤frequency detection level (n58)
Output if any of the following parameter conditions is satisfied.
• Overtorque detection function selection (n59)
• Overtorque detection level (n60)Overtorque detection level (n60)
• Overtorque detection time (n61)
Note NO contact: ON with overtorque being detected;
NC contact: OFF with overtorque being detected
ON: Alarm being detected (Nonfatal error being detected)
ON: Base block in progress (in operation with output shutoff)
ON: Local mode (with the Digital Operator)
ON: Inverter ready to operate (with no fault detected)
ON: Fault retry (Inverter resetting with fault retry (n48) not set to 0)
ON: Undervoltage being monitored
(main circuit undervoltage UV or UV1 detected)
ON: Rotating in reverse direction
ON: Speed search in progress
Note
Use "operation in progress" (set value: 1) or "idling" (set value: 3) setting for
the timing for stopping the motor using a brake. To specify a precise stop
timing, set "frequency detection 1" (set value: 4) or "frequency detection 2"
(set value: 5), and set the frequency detection level (n58).
Changes during
operation
1
Default setting
Description
Chapter 5-9