Omron VS mini J7 User Manual page 72

Compact general purpose inverter
Hide thumbs Also See for VS mini J7:
Table of Contents

Advertisement

Setting the Frequency Reference
Frequency reference
Frequency reference 1
Frequency reference 2
Frequency reference 3
Frequency reference 4
Frequency reference 5
Frequency reference 6
Frequency reference 7
Frequency reference 8
Setting the Inching Frequency Command (n29)
n29
Setting
0.0 to max. frequency
range
58
Multi-step speed
reference 1
(Set value: 6)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
No multi-step speed reference 3 settings will be required if only frequency
references 1 through 4 are used, for example. Any multi-step speed reference
not set is regarded as turned-OFF input.
The inching frequency command must be set as multi-function input in order
to use the inching frequency command.
Inching Frequency Command
Unit of
setting
Note
1. The value will be set in 0.1-Hz increments if the frequency is less than 100
Hz and 1-Hz increments if the frequency is 100 Hz or over.
2. In order to use the inching frequency command, one of the n36 through
n39 parameters for multi-function input must be set to 10 as an inching
frequency command. Parameter n29 is selectable by turning on the multi-
function input set with the inching frequency command. The inching
frequency command takes precedence over the multi-step speed
reference (i.e., when the inching frequency command is ON, all multi-step
speed reference input will be ignored).
Multi-step speed
reference 2
(Set value: 7)
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Changes during
operation
0.01 Hz
Default setting
(see note 1)
Chapter 5-5
Multi-step speed
reference 3
(Set value: 8)
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Yes
6.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J7 series

Table of Contents