Advertisement

CIMR-V7AZ
Varispeed V7
Sensorless vector in pocket size
• Nominal torque at 0.5 Hz
• Autotuning
• High carrier up to 14 khz
• Stop accuracy function.
• Integrated PID controller and bidirectional PID-out put
• Motor protection with PTC input
• Pulse input
• Standard digital operator with copy function
• Fieldbus: Modbus, DeviceNet, PROFIBUS, CANopen
• High speed motion bus: ML- II
• Plug-in PLC option unit. Total inverter access.
• CE, UL, and cUL marked
V7 IP65
• Compact size
• Easy wiring
• Built-in filter (Class B)
Customized software*
• The inverter software can be customized to meet
specific application. Examples:
• Traverse sofware S-9381.
*For detailed information please refer to case software section.
Ratings
• 200 V Class single-phase 0.1 to 4 kW
• 200 V Class three-phase 0.1 to 7.5 kW
• 400 V Class three-phase 0.2 to 7.5 kW

System configuration

3G3IV-PCN329-E
CX-Drive
Inverter to PC cable
Line filter
* V7 IP65 types are built-in filter inverters.
Varispeed V7
3G3IV-PEZZ8122_
DIN attachment
*See note
Communication unit
*See note
* Option frames are needed for V7 IP65 type.
JVOP-146
JVOP-144
Remote digital oper.
Remote digital oper.
with potentiometer
with potentiometer
Braking accessories
Varispeed
V7
PLC option unit
*See note
3G3IV-PCN126/326
Digital operator
extension cable
LKEB_
CDBR_B
ERF150WJ_
329

Advertisement

Table of Contents
loading

Summary of Contents for Omron CIMR-V7AZ

  • Page 1: System Configuration

    V7 IP65 • Compact size • Easy wiring • Built-in filter (Class B) Customized software* • The inverter software can be customized to meet specific application. Examples: • Traverse sofware S-9381. *For detailed information please refer to case software section. Ratings •...
  • Page 2: Specifications

    3-phase 200..230 V 50/60 Hz and frequency Allowable voltage -15%..+10% fluctuation Allowable frequency fluctuation Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current 400 V class 40P2 40P4 40P7 41P5 42P2...
  • Page 3 Ground fault Protected by electronic circuit (operation level is approx. 250% of rated output current) RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50 V or less. Power charge indication (Charge LED is provided for 400 V)
  • Page 4: Digital Operator

    Used to reset the inverter when an error occurs. V7 IP65 types have digital operator without frequency adjuster. The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this indicator is lit.
  • Page 5 Dimensions IP 20 type 0.1 to 4 Kw 4 M4 2 M4 (0.34) (0.34) Figure 1 Figure 2 Dimensions in mm Max. applicable Inverter model Cooling Voltage class Figure Weight kg motor output kW CIMR V7AZ method 0.12 20P1 0.25...
  • Page 6 IIP65 type 0.55 to 4 Kw 6 . 4 3x PG25 Figure 4 Max. Dimensions in mm Inverter Voltage applicable Weight Cooling model Figure class motor method CIMR V7TZ output kW 0.55 B0P405 Self cooled B0P705 Single-phase 200 V B1P505...
  • Page 7 IP65 type 0.55 to 4Kw (with option frame accessory attached) 6 . 4 Figure 5 3x PG25 2x PG12 Max. Dimensions in mm Inverter Voltage applicable Weight Cooling model Figure class motor method CIMR V7TZ output kW 0.55 B0P405 Self cooled...
  • Page 8 3x400 V 3G3MV-PFI3005-SE 3G3MV-PFI3010-SE 3G3MV-PFI3020-SE 3G3MV-PFI3030-SE Drive mounts Output flexes Dimensions Rasmi model Inverter fixing 3x200 V 3G3MV-PFI2010-E 3G3MV-PF2020-E 3G3MV-PFI2030-E 3G3MV-PFI2050-E 1x200 V 3G3MV-PFI1010-E 3G3MV-PFI1020-E 3G3MV-PFI1030-E 3G3MV-PFI1040-E 3x400 V 3G3MV-PFI3005-E 3G3MV-PFI3010-E 3G3MV-PFI3020-E 3G3MV-PFI3030-E V7 IP65 types are built-in filter inverters. Frequency inverters...
  • Page 9: Din Rail Mounting Bracket

    3G3IV-PEZZ08122C Single-phase 200 VAC CIMR-V7AZ - B0P1/ B0P2/ B0P4 3G3IV-PEZZ08122A CIMR-V7AZ - B0P7/ B1P5 3G3IV-PEZZ08122B CIMR-V7AZ - B2P2 3G3IV-PEZZ08122C CIMR-V7AZ - B4P0 3G3IV-PEZZ08122D 3-phase 400 VAC CIMR-V7AZ - 40P2/ 40P4/ 40P7/ 41P5/ 42P2 3G3IV-PEZZ08122B CIMR-V7AZ - 44P0 3G3IV-PEZZ08122C Varispeed V7...
  • Page 10 Attachments Heatsink external mounting attachment When mounting an external cooling-fan to the V7AZ, this attachment is required. Dimensions in mm Attachment CIMR-V7AZ order code V7AZ-20P1 EZZ08136A 69.2 V7AZ-20P2 V7AZ-20P4 EZZ08136B 69.2 V7AZ-20P7 EZZ08136C 69.2 V7AZ-21P5 EZZ08136D V7AZ-22P2 V7AZ-24P0 -EZZ08136F 78.6 64.4...
  • Page 11 Braking resistor unit ERF-150WJ Note: Prepare mounting screws (2-M4x8 tapped screws). Screws 8mm or more and general metric screws cannot be used. Braking resistors unit MTG screw 30 or more 30 or more Dimensions in mm Approx. Voltage Model LKEB-# weight kg MTG.screw...
  • Page 12: Installation

    S– V7 IP65 types are built-in filter. A housing is required when using the CN2 terminal on the back side of the digital operator. 1m analog input cable (code no. 3G3MV-PCN-CN2) is available for housing on request : shielded wire...
  • Page 13: Main Circuit

    Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter. R/L1, S/L2, T/L3 Do not use T/L3 of the models less than 0.75 kW for other usage, such as a junction terminal.) Inverter output For inverter output...
  • Page 14: Inverter Heat Loss

    50 mm or more or more Side spaces Top and bottom spaces 1. Always provide enough space for the main circuit or control lines including cable gland. 2. If installing inverters next to one another, provide a minimum spacing of 60mm Frequency inverters...
  • Page 15 Connections for braking resistor Braking resistor 3-phase Motor power supply Connections for braking resistor unit Overload relay trip contact Braking Use sequencer to break resistor power supply side on unit overload relay trip contact Power supply 3-phase Braking resistor unit...
  • Page 16 DC reactor DC reactor Motor 200 V class 400 V class Max. applicable Current value Inductance Max. applicable Current value Inductance motor output kW motor output kW 0.12 -------- 0.25 0.55 0.75 Frequency inverters...
  • Page 17: Ordering Information

    LKEB_ CDBR_B ERF150WJ_ * V7 IP65 types are built-in filter inverters. Communication unit PLC option unit *See note *See note * Option frames are needed for V7 IP65 type. Varispeed V7 200 V 400 V Specifications Model Specifications Model 1x200 V 0.12 Kw...
  • Page 18 3G3MV-PFI1030-SE 3G3MV-PFI1030-E B4P0 3G3MV-PFI1040-SE 3G3MV-PFI1040-E 40P2 / 40P4 3G3MV-PFI3005-SE 3G3MV-PFI3005-E 40P7 / 41P5 / 42P2 3G3MV-PFI3010-SE 3G3MV-PFI3010-E 3-Phase 400 VAC 43P0 / 44P0 3G3MV-PFI3020-SE 3G3MV-PFI3020-E 45P5 / 47P5 3G3MV-PFI3030-SE 3G3MV-PFI3030-E * V7 IP65 types are built-in filter inverters. Frequency inverters...
  • Page 19 • Host controller: TrajeXia, MCH or MP series. option card Option frame accessory is needed for V7 IP65 types when communications option units are used. For V7 IP65 types with DeviceNet communication, SI-N1/V7 should be used. Please refer to TrajeXia, MCH or MP series section for host controller technical information.
  • Page 20 9.3 (0.37) 9.3 (0.37) deep 3.5 (0.14) (1.20) 15.5 (0.61) 70 (2.76) 72606-CVS31060 Blank cover ----- 3G3IV-PEZZ0838BA Digital operator case same as JVOP-144 without operator Digital operator 3G3IV-PCN126 extension cable ----- 1 meter 3G3IV-PCN326 3 meters ----- 3G3IV-PCN329-E PC configuration cable...
  • Page 21 Braking unit, braking resistor unit Inverter Braking resistor unit Voltage Max. Inverter model Inverter-mounted type Separately-installed type applicable CIMR-V7AZ (3 %ED, 10 sec max) (10 %ED, 10 sec. max.) motor output kW Braking Model Resis- Model Resistor spec. Connectable Three- Single- No.
  • Page 22 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. I20E-EN-02 Frequency inverters...

This manual is also suitable for:

Varispeed v7

Table of Contents