5 Drive Programming User Variables
5-7
Multi-function Output Variables
You can execute the functions which can be allocated to the multi-function output terminals by using the
Drive Programming program. The following variables correspond to the functions which can be allo-
cated to the multi-function output terminals.
Setting each variable to 1 (ON) or 0 (OFF) causes the same operation as when the multi-function out-
put function turns the multi-function output terminal ON/OFF. You can monitor the status on the pro-
gram even if you do not set each function in the parameters Multi-function Output Selection (MX2:
C021 and C022/RX: C021 to C025 ) or Multi-function Relay Output (MA, MB) Function Selection
(C026). The Reference column in the following table shows the function setting data for the inverter. For
details on each function, refer to the MX2 User's Manual (I570-E2) or the RX User's Manual (I560-E2).
Precautions for Correct Use
When the Drive Programming program is stopped, the status of the multi-function output vari-
ables is not retained but updated according to the actual function status.
MX2 and RX
Function variable
RUN
FA1
FA2
OL
OD
AL
FA3
OTQ
UV
TRQ
RNT
ONT
THM
BRK
BER
ZS
DSE
POK
FA4
FA5
OL2
ODc
OIDc
FBV
NDc
LOG1
LOG 2
LOG 3
WAC
WAF
FR
OHF
5 - 20
Description
Signal during RUN
Constant speed arrival signal
Set frequency exceeded signal
Overload warning
Excessive PID deviation
Alarm signal
Set-frequency only signal
Overtorque/Undertorque signal
Signal during undervoltage
Torque limit
RUN time over
Power ON time over
Electronic thermal warning
Brake release
Brake error
0 Hz detection signal
Excessive speed deviation
Position ready
Set frequency exceeded signal 2
Set-frequency only signal 2
Overload warning 2
Analog FV disconnection detection
Analog FI disconnection detection
PID feedback comparison signal
Communications disconnection detection
Logic operation output 1
Logic operation output 2
Logic operation output 3
Capacitor life warning signal
Cooling fan life warning signal
Starting contact signal
Cooling fin overheat warning
R/W
Reference
C021 to C026 00
R
C021 to C026 01
R
C021 to C026 02
R
C021 to C026 03
R
C021 to C026 04
R
C021 to C026 05
R
C021 to C026 06
R
C021 to C026 07
R
C021 to C026 09
R
C021 to C026 10
R
C021 to C026 11
R
C021 to C026 12
R
C021 to C026 13
R
C021 to C026 19
R
C021 to C026 20
R
C021 to C026 21
R
C021 to C026 22
R
C021 to C026 23
R
C021 to C026 24
R
C021 to C026 25
R
C021 to C026 26
R
C021 to C026 27
R
C021 to C026 28
R
C021 to C026 31
R
C021 to C026 32
R
C021 to C026 33
R
C021 to C026 34
R
C021 to C026 35
R
C021 to C026 39
R
C021 to C026 40
R
C021 to C026 41
R
C021 to C026 42
R
Drive Programming User's Manual (I580-E2)