List of Parameters
Para-
Name
meter No.
(Register
No. (Hex))
n52
DC control
(0134)
current
n53
Interruption
(0135)
DC control
time
n54
Startup DC
(0136)
control time
n55
Stall
(0137)
prevention
during
deceleration
n56
Stall
(0138)
prevention
level during
acceleration
n57
Stall
(0139)
prevention
leven during
operation
n58
Frequency
(013A)
detection level
n59
Overtorque
(013B)
detection
function
selection
060
Overtorque
(013C)
detection level
061
Overtorque
(013D)
detection time
154
Description
Used to impose DC on the induction motor
for braking control.
Set the DC braking current in percentage
based on the rated current of the Inverter as
100%.
Output
frequency
Minimum
output
frequency
(n14)
n54
Used to select a function to change the
deceleration time of the motor automatically
so that there will be no overvoltage imposed
on the motor during deceleration.
0: Stall prevention during deceleration
enabled
1: Stall prevention during deceleration
disabled
Used to select a function to stop the
acceleration of the motor automatically for
stall prevention during acceleration.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to select a function to reduce the
output frequency of the Inverter
automatically for stall prevention during
operation.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to set the frequency to be detected.
Note The parameter n40 for multi-function
output must be set for the output of
frequency detection levels 1 and 2.
Used to enable or disable overtorque
detection and select the processing method
after overtorque detection.
0: Overtorque detection disabled
1: Overtorque detection only when
speed coincides and operation continues
(issues alarm)
2: Overtorque detection only when
speed coincides and output shut off
(for protection)
3: Overtorque always detected and
operation continues (issues alarm)
4: Overtorque always detected and
output shut off (for protection)
Used to set overtorque detection level.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to set the detection time of overtorque 0.1 to
Setting
Unit of
range
setting
0 to
1%
100
0.0 to
0.1 s
25.5
0.0 to
0.1 s
25.5
Time
n53
0, 1
1
30 to
1%
200
30 to
1%
200
0.0 to
0.1 Hz
400
0 to 4
1
30 to
1%
200
0.1 s
10.0
Chapter 10
Default
Changes
Refer-
setting
during
ence
operation
page
50
No
6-5
0.5
No
6-5
0.0
No
6-5
0
No
6-6
170
No
6-7
160
No
6-8
0.0
No
6-18
0
No
6-9
160
No
6-9
0.1
No
6-10