H2: Multi-Function Output

n
H2-01: Terminal MA/MB/MC Function Selection
The drive has a multi-function output terminal. Set parameter H2-01 between 0 and 13D to assign functions to this terminal.
Default values are listed in the following table.
No.
H2-01
Terminal MA, MB and MC Function Selection (relay)
Note: If not using an input terminal or if using it in the through-mode, be sure to set that terminal to "F".
Setting
Function
0
During Run
1
Zero Speed
2
Speed Agree
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
B
Torque Detection 1 (N.O.)
Setting 0: During Run
Output closes when the drive is outputting a voltage.
Status
Open
Drive is stopped.
Closed
A Run command is input or the drive is during deceleration or during DC injection.
Setting 1: Zero Speed
Terminal closes whenever the output frequency falls below the minimum output frequency set to E1-09.
Status
Open
Output frequency is above the minimum output frequency set to E1-09
Closed
Output frequency is less than the minimum output frequency set to E1-09
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
for details on how to use this function.
Parameter Name
Table 5.16 Multi-Function Output Terminal Settings
Page
95
95
96
96
96
97
97
97
97
OFF
ON
Run command
Baseblock
OFF
command
Output
frequency
OFF
ON
During Run
Figure 5.20 During Run Time Chart
Output frequency
or
motor speed
OFF
Zero Speed
Figure 5.21 Zero-Speed Time Chart
Setting Range
0 to 13D
Setting
E
Fault
F
Not used/Through Mode
10
Alarm
17
Torque Detection 1 (N.C.)
1A
During Reverse Operation
1E
Restart Enabled
3C
LOCAL/REMOTE Status
3D
During Speed Search
H2 Parameter Functions Reversed Output
100 to 13D
Switching of 0 to 92
Description
ON
Description
E1-09 (Max. Output Frequency)
ON