Omron VS mini J7 User Manual page 51

Compact general purpose inverter
Hide thumbs Also See for VS mini J7:
Table of Contents

Advertisement

Outline of Operation
Status Monitor
Item
Display
U01
Frequency reference
U02
Output frequency
U03
Output current
U04
Output voltage
U05
DC bus voltage
U06
Input terminal status
U07
Output terminal status
U09
Error log
(most recent one)
U10
Software No.
Display unit
Hz
Monitors the frequency reference. (Same as FREF)
Hz
Monitors the output frequency. (Same as FOUT)
A
Monitors the output current. (Same as IOUT)
V
Monitors the internal output voltage reference value of the
Inverter.
V
Monitors the DC voltage of the internal main circuit of the
Inverter.
---
Shows the ON/OFF status of inputs.
Not
used
---
Shows the ON/OFF status of outputs.
Not
used
---
Displays the latest error.
Error
---
OMRON use only.
Chapter 3-2
Function
: Input ON
: No input
Terminal S1: Forward/Stop
Terminal S2: Multi-function input 1 (S2)
Terminal S3: Multi-function input 2 (S3)
Terminal S4: Multi-function input 3 (S4)
Terminal S5: Multi-function input 4 (S5)
: Closed
: Open
Terminal MA: Multi-function contact
output