Analog Monitor Output

5-10 Analog Monitor Output

Setting the Analog Monitor Output (n44 and n45)
n44
Setting
0, 1
range
Set Value
Value
0
Output frequency (Reference: 10 V at max. frequency)
1
Output current (Reference: 10 V with rated output current)
n45
Setting
0.00 to 2.00
range
68
The J7AZ incorporates analog monitor output terminals AM and AC.
These terminals have analog monitor values of output frequency or current.
• The output frequency or current as a monitored item is set in n44.
• The analog output characteristics are set as an analog monitor output
gain in n45.
Analog Monitor Output
Unit of
setting
Analog Monitor Output Gain
Unit of
setting
Note
1. Set the multiplication ratio based on the set value in n44.
For example, if an output of 5 V is desired at maximum frequency
(with n44 set to 0), set n45 to 0.50.
2. The maximum output voltage of the analog monitor output terminals
are 10 V.
Changes during
operation
1
Default setting
Description
Changes during
operation
0.01
Default setting
Chapter 5-10
No
0
Yes
1.00