Configuring with the WBM
6.3 The menu items of the WBM
6.3.7

The "Settings - Communication" menu item

The "Settings - Communication" menu item is divided into two tabs. In the "XML" tab, you
can specify which data is sent via the XML interface. In the "Network interfaces" tab, you can
enable/disable the network ports (RF680/RF685R).
The "XML" tab
The "XML" tab is divided into 4 areas:
● Basic settings
● Tag events / tag commands
● RSSI events
● IO events
Figure 6-13
Basic settings
Select the "Reliable transfer" check box so that each frame (report) received from the reader
by the user application is confirmed with a reply frame. If no reply frame is received by the
reader within 10 seconds, it sends the report to the application again. Reports that are not
transferred are buffered on the reader.
With this function, you can make sure that no frames from the reader are lost even if the
connection is unstable (e.g. WLAN connection aborts occasionally).
66
The "Settings - Communication" menu item, "XML" tab
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03