Siemens SIMATIC RF650R Configuration Manual page 159

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Parameter
Parameter
value_id
value_name
value_value
value_objType
value_objName
Description of the parameters
Name
Power
RssiThreshold
Polarization
RssiDelta
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Type
Values
Decimal value
0...4294967295
0...9
Alphanumeric text
See following
table
Alphanumeric text
See following
table
Alphanumeric text
See following
table
Alphanumeric text
See following
table
objType
objName
Antenna
Antenna01
Antenna02
Antenna03
Antenna04
Antenna
Antenna01
Antenna02
Antenna03
Antenna04
Antenna
Antenna01
Antenna02
Antenna03
Antenna04
Source
See descrip-
tion
Description
Unique command identifier
Name of the supported parameter
Parameter value
Specifies the type of the parameter
groups to be addressed.
Name of the specific parameter group
Value
Description
0, 5.00...33.00
Radiated power of the antenna
in [dB]
Increment: 0.25 dB
0...255
RSSI threshold value
Transponders with lower RSSI
values are not taken into ac-
count.
This is a value without a unit
and without direct reference to
the power strength.
Default
Polarization of the antenna
Circular
Currently, this parameter can
only be set for the internal an-
Linear_vertical
tenna of the RF685R.
Linear_
horizontal
All
0...255
Difference for RSSI values
Maximum difference compared
with the RSSI value of the tran-
sponder with the highest RSSI
value that the transponders can
have and still be processed.
This is a value without a unit
and without direct reference to
the power strength.
"objName" must have the name
of the corresponding read point.
XML interface
8.3 XML commands
159